21/08/2026
ā§§āĨ¤ AC āĻā§ āĻāύ⧠āĻĒā§āϰāĻāĻžāĻļ āĻāϰāĻž āĻšā§ āĻāĻŋāύā§āϤ⧠KW-āĻ
āĻĒā§āϰāĻāĻžāĻļ āĻāϰāĻž āĻšā§ āύāĻž āĻā§āύ?
āĻāϤā§āϤāϰāĻ
āĻāϏāĻŋāĻā§ āĻāύ⧠āĻĒā§āϰāĻāĻžāĻļ āĻāϰāĻž āĻšā§ āϤāĻžāϰ āĻāĻžāϰāύ āĻšāϞ
āĻĒā§āϰāϤāĻŋ āĻāύā§āĻāĻžā§ āĻāĻŋ āĻĒāϰāĻŋāĻŽāĻžāĻŖ āϤāĻžāĻĒ āϰā§āĻŽ āĻĨā§āĻā§
remove āĻāϰāϤ⧠āĻĒāĻžāϰ⧠āĻāϰ āĻāĻĒāϰ āĻāĻŋāϤā§āϤāĻŋ āĻāϰā§
āĻāϏāĻŋāĻā§ āϤā§āϰāĻŋ āĻāϰāĻž āĻšā§āĨ¤āϤāĻžāϰ āĻŽāĻžāύ⧠āĻāĻāĻž āϤāĻžāĻĒā§āϰ
āϏāĻžāĻĨā§ āϏāĻŽā§āĻĒāϰā§āĻāĻŋāϤāĨ¤ āĻāύ āĻšāϞ āϤāĻžāĻĒā§āϰ āĻāĻāĻāĻŋ āĻāĻāĻāĨ¤
āĻā§āύ āĻāϏāĻŋ āϝāĻĻāĻŋ āĻĒā§āϰāϤāĻŋ āĻāύā§āĻāĻžā§ ā§§ā§¨ā§Ļā§Ļā§Ļ āĻŦāĻŋāĻāĻŋāĻ āĻŦāĻž
ā§§ā§Ļā§Ļā§Ļ āĻāĻŋāϞā§āĻā§āϝāĻžāϞāϰāĻŋ āĻŦāĻž ā§Ē⧧⧍ā§Ļ āĻāĻŋāϞā§āĻā§āϞ āϤāĻžāĻĒ
remove āĻāϰāϤ⧠āĻĒāĻžāϰ⧠āϤāĻžāĻā§ āĻāĻ āĻāύ āĻāϏāĻŋ āĻŦāϞā§āĨ¤
āĻāĻāύā§āύ āĻāϏāĻŋāĻā§ āĻāύ āĻšāĻŋāϏāĻžāĻŦā§ āϤā§āϰāĻŋ āĻšā§āĨ¤
BTU = British thermal āĻāĻāύāĻŋāĻāĨ¤
⧍āĨ¤ ā§§ āĻāύ āϏāĻŽāĻžāύ āĻāϤ KW ?
āĻāϤā§āϤāϰāĻ
ā§§ āĻāύ āϰā§āĻĢā§āϰāĻŋāĻāĻžāϰā§āĻļāύ āĻšāϞ āĻĒā§āϰāĻžā§ ā§§ā§¨ā§Ļā§Ļā§Ļ āĻŦāĻŋāĻāĻŋāĻ/
āĻāύā§āĻāĻž āĻāϰ āϏāĻŽāĻžāύ āĻŦāĻž ā§Šā§Ģā§§ā§Ŧ.ā§Žā§Ģā§¨ā§Ž āĻā§āĻžāĻ āĻāϰ
āϏāĻŽāĻžāύāĨ¤
One RT(Refrigeration Ton) =
3.5168528 kWâĻ
1 RT = 3.5168528 kW
āĻāĻāĻž āĻšāϞ āϤāĻžāĻĒ āĻ
āĻĒāϏāĻžāϰāύ āĻā§āώāĻŽāϤāĻžāĨ¤
āĻāĻŋāύā§āϤ⧠āĻāϞā§āĻāĻā§āϰāĻŋāĻ āĻā§āώāĻŽāϤāĻž āĻšāϞ āĻĒā§āϰāĻžā§ ā§§ā§¨ā§Ļā§Ļ āĻĨā§āĻā§
ā§§ā§Ģā§Ļā§Ļ watt.
ā§ŠāĨ¤ ⧍ āĻāύ AC-āϤ⧠āĻāϤ āĻāĻŽā§āĻĒāĻŋā§āĻžāϰ āĻāĻžāϰā§āύā§āĻ āύā§ā§
Single Phase and Three Phase-āĻ?
āĻāϤā§āϤāϰāĻ
āĻŽāύ⧠āĻāϰāĻž āϝāĻžāĻ, 230VAC and Power factor
= Cosθ = 0.95,
Single Phase AC system
1 Ton = 1.5 kW.
2 Ton = 2 x 1.5 KW =3KW
Power in a Single Phase AC System
āĻāĻŽāϰāĻž āĻāĻžāύāĻŋ,
P = VxI Cosθ=⧍ āĻāύ= 3000 āĻā§āĻžāĻ
āϤāĻžāĻšāϞā§
I = P / (V x Cosθ)âĻ.. Where Cosθ =
Power factor
I = 3000W / (230V x .95)
I(āĻāĻžāϰā§āύā§āĻ) = 13.72A
Three Phase System
āĻŽāύ⧠āĻāϰāĻž āϝāĻžāĻ,
440V and Power factor = Cosθ =
0.85 , P=⧍ āĻāύ=3000 āĻā§āĻžāĻ
āĻāĻŽāϰāĻž āĻāĻžāύāĻŋ,
P =â3 x VLxIL Cosθ
I = P /( â3xVxCosθ)
I = 3000W / (1.732 x 440V x .85)
Where Cosθ = Power factor and â3 =
1.732
I = 4.66 A
āϤāĻžāĻšāϞ⧠⧍ āĻāύ āĻāϏāĻŋ āĻāϰ āĻāĻžāϰā§āύā§āĻ āϞāĻžāĻā§ 4.66
āĻā§āĻžāĻŽā§āĻĒāĻŋā§āĻžāϰ(Three Phase)
ā§ĒāĨ¤ MCB āĻāϰ āϏāĻžāĻāĻ āĻāϤ āĻšāĻŦ⧠⧍ āĻāύ āĻ ā§§ āĻāύ āĻāϏāĻŋ
āĻāϰ āĻāύā§āϝ?
āĻāϤā§āϤāϰāĻ
āĻāĻŽāϰāĻž āĻāĻĒāϰ⧠āĻā§āϝāĻžāϞāĻā§āϞā§āĻļāύ āĻāϰ⧠āĻāĻžāϰā§āύā§āĻ āĻŦā§āϰ
āĻāϰāϞāĻžāĻŽ
Single Phase 13.72, Three phase 4.66
āϏāĻžāϧāĻžāϰāĻŖāϤ āϏā§āĻāĻžāϰāĻāĻŋāĻ āĻāϰ āϏāĻŽā§ āĻŦā§āĻļāĻŋ āĻāĻžāϰā§āύā§āĻ āĻāĻžāύā§
āĻĢā§āϞ āϞā§āĻĄ āĻāĻŦāϏā§āĻĨāĻžā§ āϏāĻŦ āĻāĻŋāĻā§ āĻŦāĻŋāĻŦā§āĻāύāĻž āĻāϰā§
āĻĻā§āĻāĻž āϝāĻžā§
āϏāĻŋāĻā§āĻā§āϞ āĻĢā§āĻ āĻāϰ āĻāύā§āϝ 25A MCB Class C
and āĻĨā§āϰāĻŋ āĻĢā§āĻā§āϰ āĻāύā§āϝ 10A Class C MCB
āĻŦā§āϝāĻŦāĻšāĻžāϰ āĻāϰāϞ⧠āĻāϞāĻŦā§