BARRETT SERVICES is aiming to provide the highest quality of service treating everyone like royalty with a high regard for respect, safety, education, honour, security and most importantly trust. BARRETT SERVICES incorporates Electrical and Communication works within the Electro technological spectrum for services in both South Australia and the Northern Territory.

14/10/2026
Assisting NBN tech to fault find. Weather plays a part in a lot of problem solving and Installation faults. Alongside wi...
11/10/2026

Assisting NBN tech to fault find.

Weather plays a part in a lot of problem solving and Installation faults.

Alongside wildlife damaging infrastructure

Found:- Broken power point rhs kitchen sink near stove- Outside light full of water- Non compliant installation behind p...
01/10/2026

Found:

- Broken power point rhs kitchen sink near stove
- Outside light full of water
- Non compliant installation behind powered point lhs kitchen sink.
- Cables to shed not maintained IP Rating
- Power point on shed wall for spa light full of water
- Non compliant IP rated join under spa decking for pump.
- Non compliant join between outlets in between lounge and microwave shelf
- Cables unprotected through steel.

10000dse generator connected to a 32a inlet with 50a double pole main switch,  then to a changeover switch. Supply from ...
29/09/2026

10000dse generator connected to a 32a inlet with 50a double pole main switch, then to a changeover switch.

Supply from grid to a 80a HFC fuse at Point of Supply (POS), then to a 63a meter isolator, and meter.
From the meter, to a 100a MAIN SWITCH, then to the changeover switch.

From the changeover switch, to a 80a circuit breaker with sub circuits.
63a to house
63a to shed
63a to carport

House has HWS and a sub circuit to an internal switchboard.

Shed has internal subcircuits.

Carport has subcircuits to a garden shed and internal lights and power.

2x new data lines in a NBN hole
29/09/2026

2x new data lines in a NBN hole

Moisture ingress, faulty pins, damaged cabling?Electrical fires can be a cause from many factors including dust, dirt, e...
29/09/2026

Moisture ingress, faulty pins, damaged cabling?

Electrical fires can be a cause from many factors including dust, dirt, excessive heat or current draw, damage hoisings or protective equipment, lack of surge protection, and lack of rcd and Circuit Breakers / rcbo protective devices.