**Servo motor move kar rahi hai, lekin position feedback stable nahi hai?**

Agar actual position reading fluctuate kar rahi ho ya positioning repeatable na ho, to feedback system ko carefully check karna zaroori hai.

Possible causes include:

- Loose encoder feedback connector
- Damaged or poorly routed feedback cable
- Electrical noise affecting the feedback signal
- Encoder or feedback device fault
- Incorrect feedback configuration
- Mechanical coupling or backlash affecting actual positioning

**Practical troubleshooting:** Drive diagnostics mein actual position aur feedback-related alarms monitor karein. Connectors, cable routing, and mechanical coupling inspect karein before replacing the encoder or servo motor.

Remember: unstable positioning can originate in the feedback circuit or the mechanical system — not necessarily the motor itself.

29/10/2026

PLC aur HMI connected hain, lekin screen par values update nahi ho rahi?

Communication connection hona aur data correctly update hona do different cheezen hain.

Possible causes:

- Incorrect PLC address or register mapping
- Wrong communication parameters
- HMI reading the wrong data type or device address
- PLC program not updating the required register
- Communication timeout or intermittent data exchange
- HMI tag configuration or refresh issue

Practical troubleshooting: Check the PLC register value directly in the programming software, then compare it with the corresponding HMI tag. This helps identify whether the issue is in the PLC logic, communication settings, or HMI configuration.

Remember: a connected cable does not guarantee correct data mapping.

28/10/2026

**Motor overload trip kar raha hai, lekin measured current normal hai?**

The problem may not be excessive motor current alone. The overload relay setting, phase imbalance, connection condition, or relay itself may need investigation.

Possible causes:

- Incorrect overload relay current setting
- Wrong relay range for the motor
- Loose or overheated terminals
- Phase imbalance or a missing phase
- Incorrect relay selection for the motor's starting method
- Faulty overload relay or incorrect wiring

**Practical tip:** Measure all three phase currents, compare them with the motor nameplate and relay settings, and check the manufacturer's trip class and wiring diagram.

Never increase the overload setting just to stop nuisance tripping. The setting must match the motor and protection requirements.

27/10/2026

⚙️ **PLC RESTARTING BY ITSELF?**

PLC achanak restart ho raha hai? Program change karne ya CPU replace karne se pehle yeh checks karein.

🔹 Power supply voltage drop
🔹 Loose terminals or damaged wiring
🔹 Electrical interference
🔹 Reset conditions and watchdog faults
🔹 CPU LEDs and diagnostic records

Har PLC ka diagnostic system different hota hai, is liye exact fault code aur controller model ko samajhna zaroori hai.

**Diagnose first. Replace only when necessary.**

YS Circuits Solution
PCB Repair | Circuit Troubleshooting | PLC Programming
📍 Karachi, Pakistan

electronics

26/10/2026

**Proximity sensor kabhi ON hota hai, kabhi OFF — aur machine ka sequence disturb ho jata hai?**

Intermittent sensor signals can cause unexpected machine stops, incorrect positioning, and sequence faults.

Possible causes include:

- Sensor-to-target distance is too large or inconsistent.
- Loose connector or damaged cable.
- Incorrect sensor mounting or target misalignment.
- Electrical noise affecting the signal.
- Unstable sensor supply voltage.
- Damaged sensor or unsuitable sensing range.

**Practical troubleshooting:** Monitor the sensor LED and PLC input status while the machine operates. If the sensor LED remains stable but the PLC input changes, investigate the wiring, supply, and input circuit.

Always follow the machine's safety procedure when checking sensors near moving parts.

25/10/2026

**IGBT test mein OK hai, phir bhi inverter overcurrent trip kar raha hai?**

An IGBT passing a basic multimeter test does not guarantee that the complete power stage is healthy.

Possible causes include:

- Faulty gate-driver circuit
- Weak or missing gate-drive signal
- Damaged gate resistor or driver supply
- Incorrect switching caused by control-circuit faults
- Current-sensing or feedback problems
- Motor cable or load-related faults

**Practical tip:** Don't stop troubleshooting after checking the IGBT. Inspect the gate-driver stage, current feedback, and the surrounding power circuit before deciding which component needs replacement.

⚠️ Inverter DC bus capacitors can retain lethal voltage after power is disconnected. Follow the manufacturer's discharge procedure and verify the voltage before working on the board.

24/10/2026

⚠️ **PCB TRACK BURNED? Don't Just Repair It — Find the Cause!**

A burnt PCB track is often a symptom of an underlying electrical problem. Simply restoring the damaged copper without identifying the root cause can lead to repeated failure.

đź”§ **What should you check?**

âś… Excessive current or a short circuit
âś… Loose or high-resistance connections
âś… Faulty MOSFETs, IGBTs or other components
âś… Damaged solder joints and terminals
âś… Correct track repair and post-repair verification

At YS Circuits Solution, we focus on systematic fault diagnosis, industrial PCB repair and electronic circuit troubleshooting.

**Fix the cause. Restore the circuit. Verify the repair.**

📍 Karachi, Pakistan
📞 0346-2438301

YS Circuits Solution
PCB Repair | Circuit Troubleshooting | PLC Programming

electronics

23/10/2026

**Power supply start hoti hai, lekin foran shutdown ho jati hai?**

This symptom does not automatically mean the PWM IC is faulty.

Possible causes include:

- Short circuit on the output rail
- Overloaded downstream circuit
- Dried or high-ESR electrolytic capacitor
- Faulty startup or auxiliary supply circuit
- Defective feedback or protection circuit
- Damaged MOSFET or secondary rectifier

**Practical troubleshooting:** Check the output for shorts first, then inspect the startup supply, switching stage, feedback circuit, and protection signals.

Remember: identify why the supply is shutting down before replacing components.

⚠️ SMPS primary circuits can retain dangerous voltage even after power is disconnected. Use appropriate isolation and discharge procedures before testing.

electronics

22/10/2026

**PCB thandi condition mein theek kaam karti hai, lekin garam hone ke baad fault aa jata hai?**

This type of intermittent fault can be difficult to diagnose because the board may pass testing when cold.

Possible causes include:

- Cracked solder joints that become unreliable with temperature changes.
- Semiconductor components with temperature-dependent faults.
- Electrolytic capacitors with degraded performance.
- Loose connectors or damaged PCB tracks.
- Thermal shutdown or protection circuits activating under heat.

**Practical tip:** Observe the board's operating temperature and fault timing. Compare measurements during cold startup and after the fault appears.

Use controlled testing and follow proper electrical safety precautions. Never apply uncontrolled heat to components just to reproduce a fault.

21/10/2026

**Relay click kar raha hai, lekin load ON nahi ho raha?**

Relay ki clicking sound sirf itna indicate karti hai ke uska mechanism operate kar raha hai. Iska matlab yeh nahi ke load ko proper supply bhi mil rahi hai.

Possible causes:

- Burnt or high-resistance relay contacts
- Loose terminal or broken PCB track
- Missing supply voltage on the contact side
- Faulty load wiring or blown fuse
- Damaged connector or solder joint

**Practical troubleshooting:** Relay coil voltage check karein, phir COM, NO aur NC contacts ko circuit diagram ke mutabiq test karein. Zaroorat par contact resistance aur load-side voltage bhi verify karein.

⚠️ Live circuit par testing sirf appropriate safety precautions aur suitable equipment ke saath karein.

Address

HOUSE # 303 Sector 13/f Orangi Town
Karachi
75800

Opening Hours

Monday 09:00 - 20:00
Tuesday 09:00 - 20:00
Wednesday 09:00 - 20:00
Thursday 09:00 - 20:00
Friday 09:00 - 20:00
Saturday 09:00 - 20:00
Sunday 12:00 - 05:00

Alerts

Be the first to know and let us send you an email when YS Circuit Solutions posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Shortcuts

Share

Nearby computer & electronics services